20. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Valve with single acting actuator with Twin Stop 20

2. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 MANUAL REVISION DATE 2

28. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 NOTES 28

29. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 NOTES 29

19. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Valve with single acting actuator Valve with double acting actuator 19

11. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 If the valve on which the control unit is installe d operates with potentially explosive products, the end user must classify the operating areas in acco rdance with ATEX Directive 199/92/EC as any valve emissions may create a potentially explosive atmosphere . Consult the attached use and maintenance manuals. 11

30. Bardiani Valvole S.p.A. via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR ) - Italy tel. +39 0525 - Fax 0525 3408 bardiani @ bardiani.com - www.bardiani.com

6. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 2 General safety warnings The J-Giotto Top® control unit for ATEX valves has bee n designed to control the pneumatically operated process valves for ATEX valves manufactured by Bardian i Valvole S.p.A.. It is possible to equip the J-Giotto Top® for ATEX valves with: • a maximum of two inductive sensors for controlling the position and up to a maximum of one solenoid valve for controlling the process valve • a maximum of one inductive sensors for controlling the position and up to a maximum of two solenoid valves for controlling the process valve For the electrical connections inside the control un it, there is a terminal board. For entry of the cable into the control unit there a re two different configurations: • threaded cable gland PG11 (for cables with a diameter of between 4 - 10.5 mm) • threaded cable gland M20x1.5 (for cables with a diameter of between 5 - 12.5mm). General warnings • Always read the technical data carefully before mach ine installation, operation and maintenance. • The J-Giotto Top® for ATEX valves must always be ins talled, operated and maintained by authorized personnel. Said personnel must know and understand both th e unit and the contents of the manual. • Take care over any separate parts of the J-Giotto T op® for ATEX valves when removing it from its packaging. • Always connect the air supply carefully and disconnec t it after use. • Always connect the power supply carefully and disconne ct it after use. • Never touch the moving parts in the J-Giotto Top® for ATEX valves or in the valves. • Always handle detergents with care. Prohibited use Use of the control unit is not envisaged: • for any operations other than those for which it w as designed. 6

1. Instruction, Use and Maintenance Manual CONTROL UNITS Bardiani Valvole S.p.A. via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR ) - Italy tel. +39 0525 400044 - fax +39 0525 3408 bardiani@bardiani.com - www.bardiani.com EN-IST-JGIOT 360 EX-0618 J-GIOTTO TOP ® ATEX

22. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 10 Troubleshooting PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Air leak from solenoid valve support No gaskets or loose fastening of the solenoid valves Check the sealing capacity of the gaskets and tighten the solenoid valve screws Air leaks in safety valve The solenoid valve does not activate Damaged solenoid valve Replace solenoid valve Air supply pressure incorrect Consult the Technical Data section in the Manual Solenoid valve support damaged Replace solenoid valve support Electrical connections not made properly Check the connections in the terminal block and tighten the screws. The inductive sensors are not working Inductive sensors damaged Replace inductive sensors Electrical connections not made properly Check the connections in the terminal block and tighten the screws. Distance between the cam and the inductive sensors greater than 1.5 mm. Check the centring of the J-Giotto and the fastening to the double guide 22

13. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 5 J-Giotto Top ® control unit for ATEX valves. NO. DESCRIPTION 21 Base 21a Sealing ring 21b Sealing ring 21d Double guide 21e Air coupling 21f Vent plug 21g Air coupling 21i Cap 21k Terminal block with support 22 Cam 25 Screw 26 Bardiani case 27a Sensor 27d Micro-size inductive sensors holder slide 114a Sleeve with cable gland PG11 114b Sleeve with cable gland M20x1.5 192 Solenoid valve 192b Solenoid valve support 192c Cap 192e Sealing ring 13

8. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Make sure, based on its classification, that the cont rol unit and its components are suitable for the application in question. The internal electrical components which can be inst alled in the J-Giotto Top® for ATEX valves must be selected based on the classification of the grou p and the zone in which the control unit will be used. Component ATEX Certiied Category Sensor PTB 01 ATEX 2191 II 1G Ex ia IIB T6 Ga II 2G EX ia IIC T6 Gb II 1D Ex ia IIIC T90°C Da Solenoid valve PTB 07 ATEX 2048 II 2G Ex ia IIC T6 Gb 8

4. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 INTRODUCTION This “Instruction, Use and Maintenance Manual” has been drawn up expressly for expert technical personnel. Consequently any information whi ch can easily be deducted from reading the text and/or examining the illustrations and/or drawin gs provided herein shall not be the object of further explanation. It forms an integral part of the Products supplied and must be read prior to any installation, operation and/or maintenance of all types of control unit provided. This manual must be saved for future reference and be kept readily available at the unit. The essential characteristics of all types of contro l unit described herein being consistent, the Manufacturer reserves the right to alter and or comple ment and or update at any time and with no obligation to notify so in writing, the data and or i nformation relevant to the use of the control unit described in this "Instruction, Use and Maintenance Manual". A constantly updated version of this "Instruction, Use and Maintenance Manual" is available at the Manufacturer's website www.bardianivalvole.it. Under no circumstance shall the Manufacturer be held liable for consequences resulting from failure and or improper use of the instructions contained in this Manual and relating to the installation, operating, maintenance and storage of the products. All rights reserved. Full or part reproduction, transfer and or recording of a ny part of this "Instruction, Use and Maintenance Manual" by all means, whether it be elect ronic, on hard copy, mechanical or any other means or recording or reuse is strictly prohibite d without the prior written consent of the Manufacturer and for any use other than that of the Buyer. TRANSLATION OF THE ORIGINAL INSTRUCTIONS DRAWN UP IN ITALIAN 4

9. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Connect the electrical components of the control unit to intrinsically safe circuits only. For further information on the components, it is mandator y to consult the relative manuals. The operating conditions of the electrical components i n the control unit are indicated in the following pdf documents attached to this manual. Description File name Sensor manual (English) 80231773UK CE certificate, sensor 8002078 EC type-examination, sensor (1D) BVS04ATEXE153 EC type-examination, sensor (1G) PTB01ATEX2191 Solenoid valve manual (German) MA6144-Manual-DE-DE 15 12 04 Solenoid valve manual (English) MA6144-Manual-EU-ML 151 2 04 CE certificate, solenoid valve SOLENOID VALVE Burkert 6510 ATEX certificate EC type-examination, solenoid valve 6144_Exi_PTB07ATEX20 48-1-2_en Permitted ambient temperature in the place of use: -10°C. ..+40°C. The temperature of the outer surfaces of the valve also depends on the fluid which flows through it. PLC ELECTRICAL BARRIER SAFE AREA HAZARDUS AREA 9

10. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Installation and assembly instructions: • abide by the relative directives and regulations in for ce • protect the J-Giotto Top® control units for ATEX val ves and the cables from damage. In the event of dropping/hitting the valve, it is compul sory to check correct operation as any friction caused by component deformation may cause malf unctions and sources of ignition. The control unit must be installed away from systems and/or places which generate stray electric currents. Mechanical damage, in most cases, results in blocked o peration; consequently there are no direct risks of ignition. Lightning protection measures and protection against cur rents caused by lightning in nearby areas are required. The control unit must not be exposed to direct sunlight . During assembly take care to ensure foreign bodies are not left inside the control unit. During assembly take care to prevent the formation of sparks caused by rubbing oxidizable substances such as iron or steel. Keep the control unit clear of any potentially explosiv e dust deposits. Do not allow dust to build up to over 5 mm in depth. 10

12. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 4 Technical data CONTROL UNIT TECHNICAL DATA Weight from 0.24 Kg to 0.42 Kg depending on the configuration Casing material PA6 GF30 dissipative Gaskets material NBR Protection class IP67 Air supply and vent connections 1/8” BSP Air line connections 6 mm / 1/4” (ON REQUEST) Electrical connections Cable gland PG11 or M20x1.5 Vibrations 1mm amplitude f=10..55Hz Storage temperature -25..+70°C Operating temperature -10...+40°C Air supply min. 6 bar .... max. 7 bar Class 2,4,3 according to ISO 8573-1 SOLENOID VALVE APPLICATION CRITERIA Single Acting Valves 1 Solenoid valve Double Acting Valves (1 normally open and 1 normally cl osed) and Twin-Stop (2 normally closed) 2 Solenoid valves SOLENOID VALVE TECHNICAL DATA See the attached instruction manuals INDUCTIVE SENSOR TECHNICAL DATA See the attached instruction manuals In the event of any doubt, please contact Bardiani Valv ole S.p.A. 12

16. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 16 21k 21 21b 21a 21

21. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Sensor HIGH Sensor LOW Solenoid valve 1 2 ATEX sensors with 1 ATEX normally closed solenoid valv e Positive (Brown) Negative (Blue) Positive (Brown) Negative (Blue) Positive (White) Negative (Brown) Positive - HIGH sensor Negative - HIGH sensor Positive - LOW sensor Negative - LOW sensor Solenoid valve 1 positive Solenoid valve 1 negative Sensor Solenoid valve 1 Solenoid valve 2 1 ATEX sensors with 2 ATEX normally closed solenoid valv es Positive (Brown) Negative (Blue) Positive (White) Negative (Brown) Positive (White) Negative (Brown) Sensor positive Sensor negative Solenoid valve 1 positive Solenoid valve 1 negative Solenoid valve 2 positive Solenoid valve 2 negative Sensor Solenoid valve N.O . Solenoid valve N.C. 1 ATEX sensor with 2 ATEX solenoid valves (1 N.C. and 1 N .O.) Positive (Brown) Negative (Blue) Positive (White) Negative (Brown) Positive (White) Negative (Brown) Sensor positive Sensor negative N.O. Solenoid valve positive N.O. Solenoid valve negative N.C. Solenoid valve positive N.C. Solenoid valve negative 9 J-Giotto Top ® electrical connections for ATEX valves 21

3. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 INDEX 1 Safety, Warning and Mandatory Signs 5 2 General safety warnings 6 3 Instructions for safe use in explosion hazard are as 7 4 Technical data 12 5 J-Giotto Top ® control unit for ATEX valves. 13 6 Disassembly / Assembly of the J-Giotto Top ® for ATEX valves 14 7 Installation of the J-Giotto Top ® for ATEX valves 17 8 J-Giotto Top ® pneumatic connections for ATEX valves. 18 9 J-Giotto Top ® electrical connections for ATEX valves 21 10 Troubleshooting 22 11 Maintenance and Cleaning 23 12 Declaration of conformity of valve complete with control unit containing at least one solenoid valve 24 13 Declaration of conformity of valve complete with control unit containing sensors only 25 14 Warranty 26 15 Recommendations 27 3

15. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Solenoid valve sequence 15 TYPE B NC NC NA 192 192c 21 x 6 192 192b 192e

7. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 3 Instructions for safe use in explosion hazard areas Use in compliance with Directive 2014/34/EC Use in explosion hazard zones in compliance with classiication: Control unit assembly without solenoid valve installed on Bardiani valve certified in accordance with Directive 2014/34/EC Group II, category 2 G c Ex ia IIB TX Group II, category 2 D c Ex ia IIIC TX It is forbidden to use the control unit in this coniguration in explosion and/or ire hazard areas classiied as Zone 0 and 20. Control unit assembly with solenoid valve installed on Bardiani valve certified in accordance with Directive 2014/34/EC Group II, category 2 G c Ex ia IIB TX It is forbidden to use the control unit in this coniguration in explosion and/or ire hazard areas classiied as Zone 0, 20, 21, 22. TX = The temperature class depends on the temperature of the working luid Filed with the Notified Body: TUV IT 07 ATEX 010 AR Rev.002 The end user is responsible for assessing the risk of explosion and classification of the unit and zone of application in accordance with Directive 1999/ 92/EC. The system on which the valve is installed must be e arthed in accordance with the regulations in force. The control unit and its components must be assembled, connected and put into service by expert personnel only. The expert personnel must have adequate knowledge of types of explosion protection, standards and regulations for means of production in explosion hazard z ones. All maintenance, assembling and installation operation s must be carried out in a potentially non-explosive atmosphere. 7

14. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 6 Disassembly / Assembly of the J-Giotto Top ® for ATEX valves 14 21d 27d 27a 21 21e 21i 21g 21f 114b 114a 21

18. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 Compressed Air inlet 1/8” (BSP) Connections for air itting 1/8” Air vent 1/8” (BSP) 8 J-Giotto Top ® pneumatic connections for ATEX valves. WARNING Use only pipes with an external diameter of 6 mm. Cut these pipes with the special cutter to avoid damaging the pipe which could lead to J-Giotto Top ® malfunctions. Select a suitable length of pipe which allows the J-Giotto Top ® to be removed without unscrewing the anchoring. 18 5

27. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 15 Recommendations 1. Consultation of the "Instruction, Use and Maintenance Manual” is mandatory prior to the installation, use and maintenance of the products of all Products. Al l the information, indications, specifications, technical details provided herein are based on test data w hich the Manufacturer Bardiani Valvole S.p.A. holds to be reliable nevertheless the above is not deeme d to be assumed as fully exhaustive inasmuch as not every possible use has been envisaged. 2. All the illustrations and drawings provided are to be inte nded as indicative and therefore not binding, the Products illustrations being for presentation purpose s only. 3. It is the Buyer's duty to assess the suitability of t he products for the use he intends to make of the same prior to placing the order as he/she will take the risks and accept liability in case of incorrect choic e and use of the Products. 4. The Manufacturer strongly recommends the Buyer to con tact their sales team and request any information that might be needed in relation to the spec ifications and uses of the Products. 5. The information provided in this manual refers to the standard products manufactured by Bardiani Valvole S.p.A. and therefore cannot be assumed to apply t o customized products as well. 6. Bardiani Valvole S.p.A. reserves the right to amend and/ or integrate and/or update the data and/ or information and/or technical details relative to P roducts at any time and without prior notice. Please visit the website www.bardiani.com , where the latest updated of the "Instruction, Use and Maintenance Manual" can be found". 7. The content and validity of the warranty covering the Products of Bardiani Valvole S.p.A are dealt with in the relevant section in the “Instruction, Use and M aintenance Manual” which constitutes an integral part of the Products themselves. 8. Bardiani Valvole S.p.A., shall not in any way be held l iable for immaterial, indirect and consequential damages, such as (by way of example only), damages or loss of business, contracts, opportunities, time, production, profits, goodwill, image etc.. 27

17. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 7 Installation of the J-Giotto Top ® for ATEX valves WARNING Always make sure that all wires are connected and sec urely fastened to the terminals and that the solenoid valves, solenoid valves support, terminal block and any other parts inside the J-Giotto Top ® for ATEX valves are well assembled and secured. WARNING Always make sure that the electrical and pneumatic co nnections are disconnected when carrying out operations on the J-Giotto Top ® for ATEX valves. 17 1 2 3 25 22 26

23. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 11 Maintenance and Cleaning When used correctly the J-Giotto Top ® for ATEX valves does not need any special maintenance . Any repair work must be carried out by authorized personn el only, making sure that the electrical and pneumatic power supplies have been disconnected before carr ying out any operation inside the J-Giotto Top ® for ATEX valves. WARNING Before using cleaning products make sure they are compat ible with the materials used to construct the J-Giotto Top ® for ATEX valves, both the casing and the gaskets. If solvents or cleaning agents containing acids or alka line substances are used, always make sure the J-Giotto Top ® for ATEX valves is immediately rinsed with clean wa ter. When so doing, pay particular attention to those areas where there are orifices or openings. WARNING Each time the casing is open, make sure that the vari ous cables inside it are repositioned where they do not interfere with cam movement. WARNING Should it be necessary to replace any component of the J-Giotto Top ® for ATEX valves, contact Bardiani Valvole S.p.A. to purchase the necessary spare part as the use of any products not supplied by us may compromise correct valve operation or constitute a ha zard for personnel. 23

5. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 1 Safety, Warning and Mandatory Signs SIGNALS Pictogram Description Notes CAUTION General This tells the person in question that the operation described involves (when not performed in accordance with the relative safety regulations) the risk of per sonal injury. OBLIGATION General Special instructions must be followed to avoid injury t o persons. SKILLED PERSONNEL Dismantling/Assembling and maintenance operations must be carried out by expert technicians only. NOTE Follow the indicated note with care ELECTRICAL CONNECTION Electrical connection to the control unit ELECTRICAL DISCONNECTION Electrical disconnection from the control unit PNEUMATIC CONNECTION Compressed air connection to the control unit PNEUMATIC DISCONNECTION Compressed air disconnection from the control unit. 5

26. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 14 Warranty 1. VALIDITY Bardiani Valvole‘s Products are manufactured in complia nce with the technical specifications laid out in their “Instruction, Use and Maintenance Manual” and are fully compliant with the directives specifically mentioned in these manuals. Bardiani Valvole S.p.A. guarantees its own Products agai nst any design and/or construction and/or material defects and/or faults for a period of 12 (twel ve) months from the date of delivery. Notification of any Product defects and/or faults must be sent in writing to Bardiani Valvole S.p.A. within 8 (eight) days from their detection, providing adequate docu mentation of the defect/fault encountered as evidence. Services provided in the warranty period shall not resul t in an extension of the warranty beyond the stipulated 12 (twelve)-month period, as this warranty v alidity period is to be considered mandatory. 2. CONTENTS OF THE WARRANTY Notwithstanding and without prejudice to the rights of th e Buyer, which may be acknowledged by applicable law, this warranty it to be intended as limite d, at the discretion of Bardiani Valvole S.p.A., to the repair and/or replacement of the Product and/or part of the Product and/or its components which is/are found to be defective due to design and/or manufact uring and/or material faults. In the event of repair and/or replacement of the Produc t and/or any one of its parts and/or components, any returned item/s shall become the property of Bardian i Valvole S.p.A. and the relative shipping costs shall charged to Bardiani Valvole S.p.A. Bardiani Valvole S.p.A., shall be under no obligation to compensate for any immaterial and/or indirect damages and shall in no way be held liable for consequenti al damages and/or losses, such as (by way of example only), damages due to loss of business, contra cts, opportunities, time, production, profits, goodwill, image etc. No retailer or distributor or dealer or agent or represe ntative or employee or person appointed by Bardiani Valvole S.p.A. is authorized to make any amen dments and/or integrations and/or extensions to this warranty. 3. WARRANTY EXCLUSIONS - Elastomers and electrical components are expressly exclu ded from this warranty. - This warranty does not cover design faults emerging when ever a Product is manufactured by Bardiani Valvole S.p.A. based on designs and/or technical specifica tions provided by the Buyer. - Moreover this warranty excludes the following: - faults and/or defects resulting from incorrect and/or u nsuitable and/or inadequate transportation of the Product; - faults and/or defects resulting from failure to comply with the indications laid out in the “Instruction, Use and Maintenance Manual” with regards to installation of the Product or in any event caused by incorrect and/or unsuitable and/or improper installation ; - faults and/or defects resulting from failure to comply with indications laid out in the “Instruction, Use and Maintenance Manual” with regards to use and/or ma intenance operations and/or storage of the Product or in any event caused by incorrect and/ or unsuitable and/or improper use and/or maintenance operations and/or storage; - faults and/or defects due to normal wear and tear of th e Product and/or its parts and/or its components; - faults and/or defects in the Product and/or its parts an d/or its components for work and/or repairs being carried out by unskilled staff or staff that has n ot been authorised by Bardiani Valvole S.p.A.; - faults and/or defects in the Product and/or its parts an d/or its components caused by its being dropped and/or banged and/or dented and/or misused and/or tampering and/ or breakage and/or accidents and/or any other event caused by negligence and/or carele ssness and/or neglect by the Buyer and in general for any causes not ascribable to design and/or ma nufacturing and/or material defects; - faults and/or defects in the Product and/or its parts an d/or its components caused by other events beyond the control of Bardiani Valvole S.p.A., such as force majeure or unforseeable circumstances. 26

24. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 12 Declaration of conformity of valve complete with control unit containing at least one solenoid valve FACSIMILE BARDIANI VALVOLE S.p.A.. Via G. di Vittorio 50/52 43045 Fornovo di Taro (Pr) EC Declaration of Conformity - Atex A9 -P- PRG - GB Ed. 1.Rev. 0 EC DECLARATION OF CONFORMITY OF THE MACHINERY ( EC ) 2006/42, Annex . II, p. 1, let. A (EU) 2014/34, Annex . X BARDIANI VALVOLE S.p.A. Via G. di Vittorio 50 /52 – 43045 Fornovo di Taro (Pr ) – Italia Declares under its own responsibility that the machine: Type : Pneumatic valves Model : Serial number : F unction : Fluid handling Year of construction: 201 7 Tech. Ref. File 949 - 01 - 00 Deposited on N.B. TUV IT 07 ATEX 010 AR Rev.002 Reference complies with all relevant provisions of the follow ing EC directives: (EC) 2006/42 MACHINERY (EU) 2014/34 ATEX and also comply with the following EC Directives an d Regulations: (EU) 2014/30 ELECTROMAGNETIC COMPATIBILITY DIRECTIV E (EMC) and the following harmonized standards, rules and / or technical specifications applied: EN ISO 12100:2010 REGULATION (EC) 1935/2004/EC and subsequent amendments and addition s with regard to steel and elastomers in contact with the produ ct REGULATION (EC) 10/2011 and subsequent amendments an d additions with regard to PTFE in contact with the product EN 1127-1:2011 EN ISO 80079- 36 EN ISO 80079- 37 EN 60079-0:20 12 EN 60079-11:2012 The equipment is classified as follows: Gr oup II, Category 2 G c Ex ia II B TX TX = The temperature class dependent on the tempera ture of the working medium. Fornovo di Taro 26.07.2018 ______________________________ Emanuela Bardiani L egal R eprese ntative 24

25. Instruction, Use and Maintenance Manual EN-IST-JGIOTEX 360-0618 13 Declaration of conformity of valve complete with control unit containing sensors only FACSIMILE BARDIANI VALVOLE S.p.A.. Via G. di Vittorio 50/52 43045 Fornovo di Taro (Pr) EC Declaration of Conformity - Atex A4 -P- PRG - GB Ed. 1. Rev. 0 EC DECLARATION OF CONFORMITY OF THE MACHINERY ( EC ) 2006/42, Annex . II, p. 1, let. A (EU) 2014/34, Annex . X BARDIANI VALVOLE S.p.A. Via G. di Vittorio 50 /52 – 43045 Fornovo di Taro (Pr ) – Italia Declares under its own responsibility that the machine: Type : Pneumatic valves Model : Serial number : F unction : Fluid handling Year of construction: 201 7 Tech. Ref. File 949 - 01 - 00 Deposited on N.B. TUV IT 07 ATEX 010 AR Rev.002 Reference complies with all relevant provisions of the follow ing EC directives: (EC) 2006/42 MACHINERY (EU) 2014/34 ATEX and also comply with the following EC Directives an d Regulations: (EU) 2014/30 ELECTROMAGNETIC COMPATIBILITY DIRECTIV E (EMC) and the following harmonized standards, rules and / or technical specifications applied: EN ISO 12100:2010 REGULATION (EC) 1935/2004/EC and subsequent amendments and addition s with regard to steel and elastomers in contact with the produ ct REGULATION (EC) 10/2011 and subsequent amendments an d additions with regard to PTFE in contact with the product EN 1127-1:2011 EN ISO 80079- 36 EN ISO 80079- 37 EN 60079-0:20 12 EN 60079-11:2012 The equipment is classified as follows: Gr oup II, Category 2 G c Ex ia II B TX Group II, C ategory 2 D c Ex ia III C TX TX = The temperature class dependent on the tempera ture of the working medium. Fornovo di Taro 26.07.2018 ______________________________ Emanuela Bardiani L egal R epresentative 25